Quote:
Originally Posted by pancake
Quick question:
Is it ok to mount the O2 sensor on the header pipe coming off of a cylinder, any cylinder, or should it be mounted at the collector?
The truck has dual exaust.
I mounted the intake and TBI adapter plate this weekend and should have the truck started again next weekend.
Thanks, Pancake.
|
You want it to sample as many cylinders as you can so it gets a good average so putting it in the collector is best. Make sure you are using a heated sensor with headers. They lose too much heat to work well with a standard O2 sensor.