Re: 4L80E & TH400 Tech.

Blocking the 2-3 Accumulator. (TH400)

You will need a 5/16-18 tap & a 5/16" set screw.
Tap it just deep enough for the set screw to seat good.

The red arrow is the accumulator feed hole that needs to be tapped & plugged.
Attached Images
  