anyone running 200psi in there tank, using a single viair 444c (max200psi) and a manual paddle switch system, the tank i have is a alloy 4 gallon one which is rated 200psi, but im worried the the pressure is to high, the vendor says it will be ok at them pressures... your thoughts please
sqweaka is offline   Reply With Quote
Old 04-22-2018, 08:52 AM   #2
47 Fasttoys
Registered User
 
47 Fasttoys's Avatar
 
Join Date: Sep 2013
Location: Westminster, SC
Posts: 933
Re: airride 200psi

I would not be concerned about 200 PSI as far as the tank goes. I left my engine driven York compressor on in manual once and was at over 275 psi in the tank when a air line let go with a loud pop. Normally the tank will have a safety factor of 2 times the listed max pressure.

Rob
__________________
My '47 C.O.E build
47 Fasttoys is offline   Reply With Quote
Old 04-22-2018, 11:20 AM   #3
e015475
Registered User
 
e015475's Avatar
 
Join Date: Nov 2013
Location: Show Low, Arizona
Posts: 749
Re: airride 200psi

Viair says the duty cycle of a single pump is 50% and the dual setup 100% at 200 psi so as long as you don't exceed the duty cycle you should be fine
e015475 is offline   Reply With Quote
Old 04-22-2018, 01:30 PM   #4
sqweaka
Registered User
 
Join Date: Mar 2015
Location: Belford uk
Posts: 120
Re: airride 200psi

Quote:
Originally Posted by e015475 View Post
Viair says the duty cycle of a single pump is 50% and the dual setup 100% at 200 psi so as long as you don't exceed the duty cycle you should be fine
quite what does that mean ... its a single pump i have
sqweaka is offline   Reply With Quote
Old 04-22-2018, 01:32 PM   #5
sqweaka
Registered User
 
Join Date: Mar 2015
Location: Belford uk
Posts: 120
Re: airride 200psi

Quote:
Originally Posted by 47 Fasttoys View Post
I would not be concerned about 200 PSI as far as the tank goes. I left my engine driven York compressor on in manual once and was at over 275 psi in the tank when a air line let go with a loud pop. Normally the tank will have a safety factor of 2 times the listed max pressure.

Rob
im more worried about the push on barb fittings on the backs of the manual paddle switches holding at 200psi, i could also fit a blow of safety valve on the tank at say 210psi
sqweaka is offline   Reply With Quote
Old 04-22-2018, 08:10 PM   #6
joedoh
Senior Member
 
joedoh's Avatar
 
Join Date: May 2007
Location: Doodah Kansas
Posts: 7,746
Re: airride 200psi

Quote:
Originally Posted by sqweaka View Post
quite what does that mean ... its a single pump i have
if the cycle is off and on, a 50% duty cycle means it has to be off half of the time, so 5 minute fill time would mean a 5 minute rest time before restarting. a 100% duty cycle can be run continuously.


Quote:
Originally Posted by sqweaka View Post
im more worried about the push on barb fittings on the backs of the manual paddle switches holding at 200psi, i could also fit a blow of safety valve on the tank at say 210psi
you can use a regulator to lower the pressures to the valves, but use a high quality one that does not limit flow rate. I would never run 200psi on a barbed fitting.
__________________
the mass of men live lives of quiet desperation


if there is a problem, I can have it.

new project WAYNE http://67-72chevytrucks.com/vboard/s...d.php?t=844393
joedoh is offline   Reply With Quote
Old 04-23-2018, 10:22 AM   #7
sqweaka
Registered User
 
Join Date: Mar 2015
Location: Belford uk
Posts: 120
Re: airride 200psi

good idea on the regulator...
the duty cycle isn't a problem as i only drive it to a show dump it then lift when i want to come home, its not up and down loads of times in a day.. during the week when im using it as a daily i just leave it at ride height!
sqweaka is offline   Reply With Quote
Old 04-23-2018, 09:40 PM   #8
Jesse Z
Account Suspended
 
Join Date: Aug 2016
Location: Florida, USA
Posts: 290
Re: airride 200psi

Dude, 200 psi is a LOT of pressure. The system begins operating on a slim safety margin. That's why most shop compressors and most semi truck air systems limit at about 125. Maybe it'll handle it, but if there are any weaknesses in the system 200 psi will sure expose them. Are you trying to substitute pressure for volume? Maybe you should upgrade to more compressor and bigger tank.
Jesse Z is offline   Reply With Quote
Old 04-24-2018, 02:05 AM   #9
sqweaka
Registered User
 
Join Date: Mar 2015
Location: Belford uk
Posts: 120
Re: airride 200psi

Quote:
Originally Posted by Jesse Z View Post
Dude, 200 psi is a LOT of pressure. The system begins operating on a slim safety margin. That's why most shop compressors and most semi truck air systems limit at about 125. Maybe it'll handle it, but if there are any weaknesses in the system 200 psi will sure expose them. Are you trying to substitute pressure for volume? Maybe you should upgrade to more compressor and bigger tank.
i agree which is why i posted on here for advice... ive tried to add volume by piggy backing a spare 2 gallon tank to the system, but it made little difference only by increasing pressure did i see improvements adding another compressor will only quicken the refill... i think
sqweaka is offline   Reply With Quote
Old 04-24-2018, 09:51 AM   #10
e015475
Registered User
 
e015475's Avatar
 
Join Date: Nov 2013
Location: Show Low, Arizona
Posts: 749
Re: airride 200psi

Sqweaka-

I guess we need to back up a little - what problem were you trying to solve by increasing the pressure to 200psi?

IIRC you have a Jag IFS on airbags. I have the same setup with a 4 gallon tank and a Viair compressor, but I'm not on the road yet. Curious on how that setup is working (or not) and what problems you're having. I have a 180PSI shutoff on a steel 4 gallon tank and a Viair compressor that will support a 100% duty cycle. I am using 3/8" hard line to plumb the tank and airbags
e015475 is offline   Reply With Quote
Reply

Bookmarks

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 09:01 AM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com