09-23-2015, 07:48 PM
|
#107
|
Old member
Join Date: Jan 2002
Location: Liberty, & Garden City S.C. , U.S.
Posts: 19,936
|
Re: Converting factory AC to use R134a
Quote:
Originally Posted by picklito
That's the chart I was using! It was 90f in the shop and after 36oz of R134 I had 240/27psi. And yes... there was a little frost...
|
I would drive it for a while and then re check if it's the same then maybe add just a touch more. I think you right on the mark pretty much though!
__________________
1971 LWB Custom, 6.0LS & 4L80E, Speedhut.com GPS speedometer & gauges with A/C. 20" Boss 338's Grey wheels 4 wheel disc brakes. My Driver
Seeing the USA in a 71
Upstate SC GM Truck Club
2013,14 and 2016 Hot Rod Pour Tour
http://upstategmtrucks.com/
Get out and drive the truck this summer and have some fun!
It sucks not being able to hear!
LWB trucks rule, if you don't think so measure your SWB!
After talking to tech support at Air Lift I have found out that the kit I need is 60811. Per the measurements I gave them. Ride height of truck inside spring and inside diameter of springs.
|
|
|