View Single Post
Old 02-21-2013, 03:39 PM   #4
LockDoc
The Older Generation


 
LockDoc's Avatar
 
Join Date: Aug 2006
Location: Montezuma, Iowa
Posts: 25,332
Re: Non AC blower motor Relay

Quote:
Originally Posted by Smitz70 View Post
Cool. Thanks Lockdoc, for the quick reply. I dont know what that relay is for but if it is not for my fan I will not worry about it right now.

One more issue.. When I move the fan switch, I get 12v at high position, nothing on the other positions. Is this the resistor?

I would think so unless your new switch is faulty. There are 2 wire coils on the resistor board, see if one of them is broken. Gently pry the wiring plug off with a small screw driver, working from side to side. It takes a 5/16 nut driver to remove the two hex head screws

Leon.
__________________
Leon

Locksmith, Specializing In Antique Trucks, Automobiles, & Motorcycles

(My Dually Pickup Project Thread)

http://67-72chevytrucks.com/vboard/s...d.php?t=829820

-
LockDoc is offline   Reply With Quote